Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
722 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
This test is not executed for ASAI adjuncts because adjuncts do not support MIMs upon which 
this test is based.
Table 244: Test #627 BRI Remote Loop Back 
Error 
Code
Test 
Result
Description / Recommendation
1000
ABRT
Could not seize the endpoint or B channels for test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1005
ABRT
The endpoint’s MIMs Supported field is administered to “no.”
1. Use change station extension to change parameter only if the 
endpoint documentation reflects support for ISDN-BRI Management 
and Maintenance Procedures.
1113
ABRT
The signaling link between the switch and the endpoint is down.
1. Use test port location long to clear any errors that prevent 
establishment of the signaling link.
2. Examine the results of the Signaling Link Status test (#626) that is run 
as part of this command.  If this test aborts or fails, follow the repair 
procedure for Test #626.
3. If the XID test (#628) continues to abort, escalate the problem.
1139
ABRT
The PN’s packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute test port long location,  and 
review the results of the BRI Port Local LAN Loop Around test (#618) 
to verify the repair.
1141
ABRT
The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance 
documentation.
2. If step 1 does not resolve the problem, escalate to the next tier.
 1 of 3