CAB-PFL (Power Fan Lead)
Issue 1 June 2005
749
 
CAB-PFL (Power Fan Lead)
G650
The CAB-PFL represents the state of a combined power/fan lead. This lead is known as the 
AuxSig lead. On a G650, the AuxSig output signal is a ground referenced relay contact closure 
indicating a failure of the 655A power supply outputs, hot spot thermal warning, hot spot thermal 
shutdown, or failure of the fan assembly in a G650. 
Use the AuxSig lead to determine the alarm state of the power supplies and fans if the serial 
bus or the interface to the serial bus of the TN2312BP IPSI in a G650 fails. If there is a 
CAB-PFL alarm in a G650 carrier, there should also be a SER-BUS, POW-SUP, CAB-TEMP, or 
PS-RGEN alarm indicating the source of the failure.
Refer to 
further information. 
When the TN2312BP IPSI is used in a CMC1 or a G600 carrier, use the CAB-PFL MO to 
determine the status of the power supply and fans, but the repair procedure should be the same 
as that for 
Note:
Note:
Fan/filter replacement procedures for the CMC1 and G600 media gateways are 
to be found under 
 in Maintenance Procedures (03-300192).
Error log entries and test-to-clear values
Note:
a. Error Type 1—The AuxSig lead is active. Run test environment location and follow 
the repair steps for Test #1533.
MOs name (in 
alarm log)
Alarm
level
Initial SAT command to run
Full name of MO
CAB-PFL
MIN
test environment location
Power Fan Lead
CAB-PFL
MAJ
test environment location
Power Fan Lead
Table 257: CAB-PFL Error Log Entries
Error 
Type
Aux 
data
Associated test
Alarm 
level
1
1. The alarm level of CAB-PFL is adjusted to be the same as the highest active alarm level for SER-BUS, 
POW-SUP, CAB-TEMP, or PS-RGEN, or it will be a MAJOR alarm if no G650 alarms in that category are 
found.
On/Off
board
Test-to-clear value
1 (
Power/Fan lead query 
test (#1533)
MAJ
MIN
OFF
test environment 
location