CAB-MTCE (Media Gateway Maintenance)
Issue 1 June 2005
747
 
1982
ABRT
The board being tested is NOT a TN2312BP IPSI or later.
1. Insert a TN2312BP IPSI circuit pack.
1986
ABRT
The TN2312BP IPSI failed to set emergency transfer to AUTO at 
initialization.
1. Enter reset maintenance
2. If the reset maintenance command aborts again enter set emergency 
command to see if emergency transfer can be activated or deactivated.
3. If the reset maintenance command continues to abort escalate the 
problem.  
2000
ABRT
The response to a query was not received in the time allowed. 
1. Run reset maintenance
2. Escalate the problem if the test continues to abort.
2500
ABRT
An internal operation failed (Possible unknown cabinet type).
1. Repeat the command at one-minute intervals 1 to 3 times.
2. Escalate the problem if the test continues to abort.
1
FAIL
The TN2312BP IPSI environmental maintenance initialization failed.
1. Repeat the command at one-minute intervals 1 to 3 times.
2
FAIL
The TN2312BP IPSI failed a sanity test.
1. Run reset maint command.
2. If the problem persists, replace the circuit pack.
 PASS 
Environmental 
maintenance 
has 
been enabled and passes a sanity test. 
Table 254: Test #1545 Reset test  (continued)
Error 
code
Test 
result
Description and recommendation
 2 of 2