CLSFY-PT (Call Classifier Port)
Issue 1 June 2005
811
 
CLSFY-PT (Call Classifier Port)
S8700 | 8710
 / 
S8500
The TN744 Call Classifier is a service circuit pack that provides specialized tone detection 
capabilities to support the Outbound Call Management (OCM) and Inbound Call Management 
(ICM) features.  The TN744 supports both A-law and Mu-law companding.
The TN744 has eight ports (CLSFY-PTs), each capable of supporting call classification, 
touch-tone reception and MFC-tone generation and detection.  The CLSFY-PT MO implements 
a set of tests designed to ensure proper operation of the Call Classifier.
Error Log Entries and Test to Clear Values
Notes:
a. A major alarm is raised if the total number of call classifier ports currently in-service is less 
than or equal to 1/2 of the administered threshold number.  For major or minor alarm,  run 
the short test sequence on the alarmed port and follow the error code procedures for the 
individual tests.
The in-service threshold number for alarming call classifier ports is administered using the 
change system-parameters maintenance.
MO Name in Alarm Log Alarm 
Level
Initial Command to Run
Full Name of MO
CLSFY-PT
MAJ
test port location sh
Call Classifier Port
CLSFY-PT MIN
test port location sh
Call Classifier Port
CLSFY-PT WRN
test port location sh
Call Classifier Port
Table 278: Call Classifier Port (CLSFY-PT) Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1
any
Tone Detector Audit/
Update test (#43)
MAJ / MIN 
ON
test port location r 2
18
busyout port
WRN
OFF
release port location
257 (
17666
Tone Detection Audit 
Update test (#43)
MAJ / MIN 
ON
test port location r 3
513 (
)
any
Tone Detection
Verification test (#42)
MAJ / MIN 
ON
test port location r 3