CLSFY-PT (Call Classifier Port)
Issue 1 June 2005
815
 
Tone Detector Audit/Update Test (#43)
This test performs a sanity audit on the CLSFY-PT (Call Classifier Port).
Table 280: Test #43 Tone Detector Audit/Update Test 
Error 
Code
Test 
Result
Description / Recommendation
none
ABRT
The system was not able to allocate the resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Hardware audit failed.
1. Enter these commands in order: busyout boardreset board
release board.  The board reset is required to reload on-board RAM 
associated with the TN744’s DSPs.  This takes all 8 Tone Detector 
ports out of service for a few seconds.  Only 4 of the 8 would be out of 
service due to the alarm.  (There are five Tone Detectors on each of the 
two DSPs.) Other than the unlikely potential of running out of Tone 
Detector resources in the switch, there is no other effect when the 
board is reset.
2. Test the board with test board location long.
3. If the test still fails, replace the board.
PASS
The call classifier port has passed the sanity inquiry.