Communication Manager Maintenance-Object Repair Procedures
826 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1018
ABRT
The test was disabled via translation.  You may want to determine why the 
test has been disabled before you enable it.
1. Verify that the Maintenance Test field on the Trunk Administration 
form is set to n. To enable the test, change the trunk administration and 
enter y into the Maintenance Test field.
2. Repeat the test.
1020
ABRT
The test did not run due to a previously existing error on the specific port or 
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the previously existing error.
1412
ABRT
This test does not execute on a G700/G350 Media Gateway.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABRT
At least one of the following errors was found on the DS1 circuit pack:  Loss 
of signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm (2305), 
or Hyperactivity (1537).
Look for the previous error types in the Hardware Error Log, and follow the 
procedures given in the appropriate DS1-BD or UDS1-BD maintenance 
documentation for the listed error types.
Table 283: Test #7 Conference Circuit Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 4