824 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Conference Circuit Test (#7)
Note:
Note:
S8300
 / 
G700
: This test aborts with Error Code 1412.
The Conference Circuit test verifies that the NPE channel for the port being tested can correctly 
perform the conferencing function.  The NPE is instructed to listen to several different tones and 
conference the tones together.  The resulting signal is then measured by a Tone Detector port.  
If the level of the tone is within a certain range, the test passes.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).  This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, an insane board is inserted, or the board is hyperactive.
1. Verify that the board’s translations are correct.  Enter list config
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter busyout 
board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port.  If 
not, dispatch to verify that a valid board is inserted.
Note:
Note:
Hyperactivity causes some special problems with the 
sequence suggested above.  If the ports are translated after 
entering list config but the Vintage field reports that 
there is no board (when there really is a board), then 
busyout board and release board do not work, but  
reset board location works.  The software puts the 
hyperactive board back in service after the hyperactivity 
clears.
Table 282: Test #6 NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation