Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
830 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
PASS
Trunk translation has been updated successfully.  The current trunk states 
kept in the DS1 Interface circuit pack or media module and switch software 
are consistent.  If the trunk is busied out, the test will not run but will return 
PASS.  To verify that the trunk is in-service:
1. Enter status trunk to verify that the trunk is in-service.  If the trunk 
is in-service, no further action is necessary.  If the trunk is 
out-of-service.
2. Enter release trunk to put the trunk back into in-service.
3. Retry the test command.
0
NO
BOARD
The test could not relate the internal ID to the port.  This result could be due 
to incorrect translations, no board inserted, an incorrect board inserted, an 
insane board inserted, or the board is hyperactive.
1. Verify that the board’s translations are correct.  Enter list config
and resolve any problems that are found.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port.  If 
not, dispatch to verify that a valid board is inserted.
Hyperactivity causes some special problems with the sequence suggested 
above.  If the ports are translated after issuing list config but the 
Vintage field reports that there is no board (when there really is a board), 
then busyout board and release board do not work, even though 
reset board does work.  The software puts the hyperactive board back in 
service after the hyperactivity clears.
Table 284: Test #36 Port Audit and Update Test  (continued)
Error 
Code
Test 
Resul
t
Description / Recommendation
 2 of 2