Communication Manager Maintenance-Object Repair Procedures
832 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1004
ABRT
The test was aborted because the port was seized by a user for a valid 
call.
1. Use display port location to determine the trunk group/
member number of the port.  Use status trunk to determine the 
service state of the port.  If the port is active, wait until it is idle before 
testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
1005
ABRT
Test failed due to incompatible configuration administered in trunk group 
screen.
1. Look at the trunk group administration form and see whether the trunk 
is incoming only, port 24 on a DS1 Interface with common control 
channel signaling, or an automatic CO type such as FX.  Under any of 
these conditions this is a normal abort.
1018
ABRT
Test is disabled via translation.  You may want to determine why the test 
has been disabled before you enable it.
1. Verify that the Maintenance Test field on the Trunk Group 
screen is n.  To enable the test, enter change trunk-group <x> 
(<x> is the number of the trunk group to be tested).  Change the 
Maintenance Test field on the screen to y.
2. Repeat the test.
1020
ABRT
The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD/UDS1-BD errors in the Hardware Error Log.  If 
present, see the appropriate DS1-BD/UDS1-BD (DS1/UDS1 Trunk 
circuit pack).
2. Retry the command.
1040
ABRT
The test was aborted because this port may be an access endpoint.
1. Verify that this port is an access endpoint by issuing display port  
location
2. If the port has been administered as an access endpoint, then this is a 
normal abort.
Table 285: Test #314 DS1 CO Dial Tone Seizure Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4