CO-TRK (Analog CO Trunk)
Issue 1 June 2005
861
 
1947
ABRT
Noise with tone self check failed.
1. Test the TN771 circuit packs or.
2000
ABRT
The test timed out while waiting for a response from the TN771 circuit 
pack.
Retry the command at 1-minute intervals up to 5 times.
2012
ABRT
An internal software error occurred.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABRT
The test call could not be established, but an explanation is unavailable.
1. Retry the command at 1-minute intervals up to 5 times.
2056
ABRT
An error occurred while trying to obtain results from the TN771 circuit pack.
Test the TN771 circuit packs.
FAIL
Measured transmission performance was in the unacceptable range as 
administered on the trunk group screen.  Retrieve a measurement report via 
list testcalls.  Make sure that ATMS thresholds are set properly on 
page 4 of the trunk group screen.  Besides the facility, test failures can be 
caused by faulty test lines or switch paths.  If the measurements point to a 
facility problem, report the results to the trunk vendor.
8000
FAIL
Measured transmission performance was in the marginal range as 
administered on the trunk group screen.  This generally means that the 
trunk is usable but has an undesirable amount of noise or loss.  If the user 
does not report unacceptable effects, it may not be necessary to take any 
action.  Retrieve a measurement report via list testcalls.  Make sure 
that ATMS thresholds are set properly on page 4 of the trunk group screen.
Table 293: Test #844-848 Transmission Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 4