CO-TRK (Analog CO Trunk)
Issue 1 June 2005
861
1947
ABRT
Noise with tone self check failed.
1. Test the TN771 circuit packs or.
2000
ABRT
The test timed out while waiting for a response from the TN771 circuit
pack.
pack.
Retry the command at 1-minute intervals up to 5 times.
2012
ABRT
An internal software error occurred.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABRT
The test call could not be established, but an explanation is unavailable.
1. Retry the command at 1-minute intervals up to 5 times.
2056
ABRT
An error occurred while trying to obtain results from the TN771 circuit pack.
Test the TN771 circuit packs.
FAIL
Measured transmission performance was in the unacceptable range as
administered on the trunk group screen. Retrieve a measurement report via
list testcalls. Make sure that ATMS thresholds are set properly on
page 4 of the trunk group screen. Besides the facility, test failures can be
caused by faulty test lines or switch paths. If the measurements point to a
facility problem, report the results to the trunk vendor.
8000
FAIL
Measured transmission performance was in the marginal range as
administered on the trunk group screen. This generally means that the
trunk is usable but has an undesirable amount of noise or loss. If the user
does not report unacceptable effects, it may not be necessary to take any
action. Retrieve a measurement report via list testcalls. Make sure
that ATMS thresholds are set properly on page 4 of the trunk group screen.
Table 293: Test #844-848 Transmission Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
4 of 4