Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
862 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
CONFIG (System Configuration)
S8700 | 8710
 / 
S8500
The System Configuration MO oversees logical insertion and removal of circuit packs in the 
system.  When Switch Control detects that a circuit pack is present in a port slot, it informs 
System Configuration and System Configuration queries the circuit pack to determine the type 
and vintage of the circuit pack.  Similarly, when Switch Control detects that a circuit pack has 
been removed from a port slot, it informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors are logged to 
the Hardware Error Log.
Error Log Entries and Test to Clear Values
Notes:
a. This error should not occur.  It indicates that an attempt was made by software to raise an 
alarm against CONFIG without first logging a CONFIG error.
b. Error Types 1-119: a port circuit pack in the system did not respond to a circuit pack type 
inquiry.  Follow the procedures outlined in (c) to determine whether there is an error.
c. Error Type 257:  less than 25% of trunk group is available.
MO Name in Alarm Log
Alarm 
Level
Initial Command to Run
Full Name of MO
CONFIG
none
none
System Configuration
Table 294: System Configuration Error Log Entries
Error Type
Aux 
Data
Associated 
Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
0
none
none
N/A
none
1–119 (
0–21
none
257 (
none
MAJ
1001–1119 (
0–21
none