Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
870 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
DAT-LINE (Data Line Port)
S8700 | 8710
 / 
S8500
The TN726 Data Line circuit pack has eight ports, each of which supports an RS-232 interface 
to asynchronous CPE (customer-premises equipment). Each of these ports and the equipment 
connected to it constitute a data line. For DT-LN-BD (Data Line circuit pack) errors, see 
on page 2539. Check circuit pack-level errors first 
since the usability of the ports depend on the health of the circuit pack.
Use add data-module to administer data line ports at the terminal. The data module type is 
data-line. The list data-module command shows every administered data module in the 
system.
The TN750 Announcement circuit pack has one data line-type port on it. This data line port is 
used for saving and restoring announcements. This data line port is not supported on the S8500 
and S8700 media server products. For a description of and repair instructions for the TN750, 
see 
Note:
Note:
If the tests for the data line port in question pass, and user-reported complaints 
persist, there is probably an external problem. Test the ADU (asynchronous data 
unit), using the procedures in 
. If the ADU appears to be working properly, check the external 
wiring, then check the equipment.
Error Log Entries and Test to Clear Values
MO Name in 
Alarm Log
Alarm
Level
Initial SAT Command to Run
Full Name of MO
DAT-LINE
MIN
test port location l
Data Line port
DAT-LINE
WRN
test port location l
Data Line port
Table 296: Data Line Port Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
)
0
Any
Any
Any
test port location sh r 1
1
Digital 
Looparound test 
(#171)
MIN
ON
test port location s r 2
 1 of 2