Avaya 03-300430 User Manual

Page of 2574
DAT-LINE (Data Line Port)
Issue 1 June 2005
871
 
Notes:
a. Error Type 0
Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its recommended procedures.
b. Error Type 15: This is a software audit error that does not indicate any hardware 
malfunction. Run the short test sequence, and investigate errors.
c. Error Type 130: the circuit pack has been removed or has been insane for more than 
11-minutes. To clear the error, reseat or replace the circuit pack.
d. Error Type 769: the data line circuit pack found an error in the transmit/receive circuitry of 
an administered data line when the circuit pack was inserted. Perform the following:
1. Enter busyout board location for the circuit pack on which the port resides.
2. Enter reset board location. Check the Error Log to determine whether Error Type 
#769 is logged again for DAT-LINE. Verify that the Active Alarms Only field is n.
If Error Type #769 reappears, replace the data line circuit pack. If not, proceed to Step 
.
3. Enter release board location.
15(
Any
Audit Update test 
(#36)
18
0
busyout port 
location
WRN
OFF
rel port location
130 (
None
WRN
ON
test port location sh
257
Conference 
Circuit test (#7)
MIN
ON
test port location l r 2
513
NPE Crosstalk 
test (#6)
MIN
ON
test port location l r 2
769(
40983
None
Table 296: Data Line Port Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 2 of 2