Avaya 03-300430 User Manual
DAT-LINE (Data Line Port)
Issue 1 June 2005
871
Notes:
a. Error Type 0
:
Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its recommended procedures.
b. Error Type 15: This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate errors.
c. Error Type 130: the circuit pack has been removed or has been insane for more than
11-minutes. To clear the error, reseat or replace the circuit pack.
d. Error Type 769: the data line circuit pack found an error in the transmit/receive circuitry of
an administered data line when the circuit pack was inserted. Perform the following:
1. Enter busyout board location for the circuit pack on which the port resides.
2. Enter reset board location. Check the Error Log to determine whether Error Type
2. Enter reset board location. Check the Error Log to determine whether Error Type
#769 is logged again for DAT-LINE. Verify that the Active Alarms Only field is n.
If Error Type #769 reappears, replace the data line circuit pack. If not, proceed to Step
.
3. Enter release board location.
15(
Any
Audit Update test
(#36)
18
0
busyout port
location
WRN
OFF
rel port location
130 (
None
WRN
ON
test port location sh
257
Conference
Circuit test (#7)
MIN
ON
test port location l r 2
513
NPE Crosstalk
test (#6)
MIN
ON
test port location l r 2
769(
40983
None
Table 296: Data Line Port Error Log Entries (continued)
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
2 of 2