Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
892 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Conference Circuit Test (#7)
Note:
Note:
S8300
 / 
G700
 This test aborts with Error Code 1412.
The Conference Circuit test verifies that the NPE channel for the port being tested can correctly 
perform the conferencing function. The NPE is instructed to listen to several different tones and 
conference the tones together.
0
NO
BOARD
The test could not relate the internal ID to the port. This could be due to 
incorrect translations, no board is inserted, an incorrect board is inserted, 
or an insane board is inserted.
1. Verify that the board translations are correct. Enter list config, 
and resolve any problems that are found.
2. Enter busyout board location
Enter reset board location
Enter release board location
3. Enter test board location long
This should re-establish the link between the internal ID and the port. If 
not, check to see that there is a valid board inserted.
Table 304: Test #6 NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 4
Table 305: Test #7 Conference Circuit Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 4