DID-DS1 (Direct Inward Dial Trunk)
Issue 1 June 2005
893
 
1000
ABRT
System resources required for this test were not available. The port may 
be busy with a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the 
service state of the port. If the port is in use, wait until it is idle before 
testing.
2. If the port status is active but the port is idle (no calls), check the error 
log for Error Type #1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or it may have time slots out of service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic 
and the port status is idle, retry the command at 1-minute intervals up 
to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Enter list measurements tone-receiver to display information 
about the tone receivers.
2. Resolve any TTR-LEV errors.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a user for a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the 
service state of the port. If the port is in use, wait until it is idle before 
testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
Table 305: Test #7 Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4