Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
906 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 309: Test #33 Loop-Around and Conference Circuit Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test. This 
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
3
ABRT
System resources required to run this test are not available. The seized 
tone detector did not respond. This abort code is usually associated with 
tone-clock (TONE-BD, TONE-PT, and TDM-CLK) resources.
1. Clear any tone errors in the error log.
2. Retry the command a 1-minute intervals up to 5 times.
3. If the test continues to abort, escalate the problem.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Enter display port location to determine the station extension, 
attendant number, or trunk group/member number of the port. Use 
status stationstatus attendant, or status trunk to 
determine the service state of the port. If the port is in use, wait until it 
is idle before testing. Attendants are always in use (off-hook) if the 
handset is plugged in and the port is not busied out.
2. If the port status is active but the port is idle (no calls), check the Error 
Log for Error Type 513. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
1004
ABRT
The port was seized by a valid call during the test.
1. Enter display port location to determine the station extension, 
attendant number, or trunk group/member number of the port. Use 
status stationstatus attendant, or status trunk to 
determine the service state of the port. If the port is in use, wait until it 
is idle before testing. Attendants are always in use (off-hook), if the 
handset is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals up to 5 times.
 1 of 5