Avaya 03-300430 User Manual

Page of 2574
DID-TRK (Direct Inward Dial Trunk)
Issue 1 June 2005
905
 
Looparound and Conference Circuit Test (#33)
Note:
Note:
S8300
 / 
G700
: This test aborts with Error Code 1412.
This test checks the reflective and non-reflective loop-around and conference capabilities of a 
DID port circuit. The test that uses 404-, 1004-, and 2804-Hz tones is an on-board test only. 
Each tone is separately transmitted to and from the port (loop around within the port) and 
verified.
This test may fail due to noise induced by adjacent electric power lines. Resolve this problem 
with the local power company. To temporarily alleviate the alarm caused by the failure of this 
test, disable the test from the trunk administration Test field. This also disables the port 
diagnostic test.
Any
FAIL
This test can fail due to off-board problems, including EXP-PN and 
EXP-INTF faults RMC-ENV faults (
S8700 IP
), TDM-BUS faults, and Tone 
Detectors/Tone Generators. Clear every off-board problem before 
replacing the board. A TDM-BUS problem is usually a faulty board or bent 
pins on the backplane.
1. Resolve any EXP-PN and EXP-INTF, RMC-ENV (
S8700 IP
), TDM-BUS, 
TONE-BD, and TONE-PT errors in the error log.
2. Retest the board. Replace the board if the test fails.
PASS
The port is correctly using its allocated time slots. User-reported troubles on 
this port should be investigated using other port tests and by examining 
station, trunk, or external wiring.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board if 
necessary.
2. Enter busyout board location.
3. Enter reset board location.
4. Enter release board location.
5. Enter test board location.
This should re-establish the linkage between the internal ID and the 
port.
Table 308: Test #6 NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation