DID-TRK (Direct Inward Dial Trunk)
Issue 1 June 2005
909
 
131
The reflective 1004-Hz tone test failed. Poor-quality transmission was 
detected to or from the port. The problem may be off-board. See additional 
information for this error code below.
!
CAUTION:
CAUTION:
The port may still be operational, or the fault may be 
off-board (connections or CO). Off-board problems include 
incoming seizures or off-hook port seizures during the test 
and, perhaps, noise induced by adjacent electric power 
lines. The test may be disabled from the trunk 
administration 'Test' field. This turns off all testing for that 
trunk group except for tests 6 and 36.
133
The reflective 2804-Hz tone test failed. Poor-quality transmission was 
detected to or from the port. The problem may be off-board. See additional 
information for this error code below.
!
CAUTION:
CAUTION:
The port may still be operational, or the fault may be 
off-board (connections or CO). Off-board problems include 
incoming seizures or off-hook port seizures during the test 
and, perhaps, noise induced by adjacent electric power 
lines. The test may be disabled from the trunk 
administration 'Test' field. This turns off all testing for that 
trunk group except for tests 6 and 36.
Table 309: Test #33 Loop-Around and Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation