DIOD-TRK (DIOD Trunk)
Issue 1 June 2005
971
 
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Enter display port location to determine the trunk group/
member number of the port. Use status trunk to determine the 
service state of the port. If the port is in use, wait until it is idle before 
retesting.
S8300
G700
1412
ABRT
This test does not execute on a G700 Media Gateway.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This 
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported troubles on 
this port should be investigated by using other port tests and by examining 
trunk or external wiring.