Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
972 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Looparound and Conference Circuit Test (#33)
Note:
Note:
S8300
 / 
G700
:
 This test aborts with Error Code 1412.
This test checks the reflective loop and conference abilities of a CO port circuit. The test uses 
404-, 1004-, and 2804-Hz tones. Each tone is transmitted separately through the loop and 
checked.
Table 335: Test #33 Looparound and Conference Circuit Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate system resources to run this test.
7
ABRT
Conference Circuit test aborted.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Enter display port location to determine the trunk group/
member number of the port. Use status trunk to determine the 
service state of the port. If the port is unavailable, wait until it is idle 
before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5 
times.
1004
ABRT
The port has been seized by a user for a valid call. Use status trunk to 
determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
S8300
G700
1412
ABRT
This test does not execute on a G700 Media Gateway.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2