Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
972 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Looparound and Conference Circuit Test (#33)
Note:
Note:
S8300
/
G700
:
This test aborts with Error Code 1412.
This test checks the reflective loop and conference abilities of a CO port circuit. The test uses
404-, 1004-, and 2804-Hz tones. Each tone is transmitted separately through the loop and
checked.
404-, 1004-, and 2804-Hz tones. Each tone is transmitted separately through the loop and
checked.
Table 335: Test #33 Looparound and Conference Circuit Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
ABRT
Could not allocate system resources to run this test.
7
ABRT
Conference Circuit test aborted.
1000
ABRT
System resources required to run this test are not available. The port may
be busy with a valid call.
be busy with a valid call.
1. Enter display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is unavailable, wait until it is idle
before testing.
before testing.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1004
ABRT
The port has been seized by a user for a valid call. Use status trunk to
determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
S8300
G700
G700
1412
ABRT
This test does not execute on a G700 Media Gateway.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2