Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 15.0  
System Reporting Information 
EN | 65 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
When the Swinger Shutdown Count is reached, all 
zones that were activated are locked out according to 
their individual lockout settings. 
 
If Lockout Dialer is enabled for any zone, 
the last restore signal is not transmitted 
until the system is disarmed. 
If the ICP-CC488 Control Panel is 
partitioned, the Swinger Shutdown Count 
for Dialer applies to both Area 1 and 
Area 2. 
Example 
All eight zones are programmed for lockout dialer 
with a Swinger Shutdown Count of 6. If Zone 1 
activates an alarm, the Swinger Shutdown Count 
decrements to 5 when the control panel calls.   
If Zone 1 reactivates the dialer, the Swinger 
Shutdown Count is decremented by to 4. If Zone 1 
reactivates the dialer three more times, the Swinger 
Shutdown Count is 1. 
If Zone 2 activates an alarm, the Swinger Shutdown 
Count is decremented to 0, which locks out Zone 2 
from activating the dialer until the system is reset. At 
this point, the Swinger Shutdown Count for the 
Dialer is reset to 6 and the process of swinger 
shutdown for the remaining zones, including Zone 1, 
begins again until all zones are locked out. 
15.0  System Reporting 
Information 
This section covers features that are involved with 
basic housekeeping of the system. These include 
monitoring of the zones, whether they are isolated 
from the system or are actually operating, the status 
of the AC MAINS and DC power to the system, and 
codepad-generated alarms activated by the user. 
15.1  Zone Status – Zone Tamper Report 
Location 
381 to 382 
 Location 
Default 
Zone Tamper Report 
381 
Zone Tamper Restore Report 
382 0 
A Zone Tamper Report (Contact ID Event Code 
144) is sent when Option 14 is programmed in 
Location 266 (refer to Section 14.2 EOL Resistor Value 
on page 56) and the zone loop using split EOL 
resistors (3K3/6K8) with tamper (1K) becomes open 
circuit.  
To enable Zone Tamper and Zone Tamper 
Restore Reports, program the two locations with 
any digit from 1 to 15. 
 
 
15.2  Zone Status – Walk Test Report 
Location
383 to 384 
 Location 
Default 
Walk Test Report 
383 
Walk Test Restore Report 
384 0 
A Walk Test Report (Contact ID Event Code 607) is 
sent when either the Installer or Master Code holder 
activates Walk Test Mode (refer to Section 5.1.8 on 
page 26 or Section 5.2.9 on page 31 for more 
information). 
To enable Walk Test and Walk Test Restore Reports, 
program the two locations with any digit from 1 to 
15. 
15.3  Zone Status – Bypass Reports 
Location
385 to 386 
 Location 
Default 
Zone Bypass Report 
385 
Zone Bypass Restore Report 
386 8 
A zone is bypassed when it is manually isolated. 
Refer to Section 3.11 Isolating Zones on page 17 for 
information on isolating zones. A Zone Bypass 
Report (Contact ID Event Code 573) is sent at the 
end of Exit Time for any zone that was manually 
isolated. A 24-Hour Zone sends a Zone Bypass 
Report when the zone is selected to be isolated. 
A Zone Bypass Restore Report is sent when the 
system is disarmed. All bypassed zones are 
automatically cleared when the system is disarmed.  
The Bypass code parameter has no effect on Contact 
ID Format because a Zone Bypass is always reported 
as Event Code 570. 
 
If Zone Bypass Reports are not required, 
program Locations 385 and 386 as 0. 
A 24-Hour Burglary Zone that is manually 
bypassed reports as Contact ID Event 
Code 572.  
A 24-Hour Fire Zone that is manually 
bypassed reports as Contact ID Event 
Code 571. 
15.4  Zone Status – Trouble Reports 
Location
387 to 388 
 Location 
Default 
Zone Trouble Report 
387 
Zone Trouble Restore Report 
388 3 
A zone is in trouble when it is unsealed at the end of 
Exit Time. A Sensor Trouble Report (Contact ID 
Event Code 380) is sent to indicate that one or more 
zones were automatically isolated by the system. 24-
Hour Zones that are unsealed at the end of Exit Time 
do not transmit a Sensor Trouble Report because the 
restoral for that zone is still outstanding.