Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 15.0  
System Reporting Information 
EN | 67 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
An RF Receiver Trouble Report (Contact ID Event 
Code 355) is sent to the base station receiver when 
the RF receiver registers one of these events: 
RF Signal Jamming (Point ID Code 001) 
RF Receiver Tamper Switch (Point ID Code 002) 
RF Receiver Failure (Point ID Code 003) 
15.11  RF Receiver Trouble Restore 
Report 
Location 
398 to 399 
 Location 
Default 
Tens digit 
398 
Units digit 
399 11 
An RF Receiver Trouble Restore Report is sent to 
the base station receiver when the RF receiver no 
longer registers RF Signal Jamming, RF Receiver 
Tamper Switch, or RF Receiver Failure. 
15.12  RF Dialer Options 
Location 
400 
No report allowed 
Report to Receiver 1 
Report to Receiver 2 
Report to both Receiver 1 and Receiver 2 
Report to Receiver 2 only if Receiver 1 fails 
Location 400 is set by default to report only to 
Receiver 1. You can select whether Zone Status 
Reports are sent to Receiver 1, Receiver 2, or both, 
Receiver 2 only when Receiver 1 fails, or there is no 
reporting at all. 
15.13 Open/Close Reports 
Location 
401 to 402 
 Location 
Default 
Open Report 
401 
11 
Close Report 
402 12 
An Opening Report (Contact ID Event Code 401) is 
sent to the base station receiver when the system is 
disarmed from AWAY Mode. A Closing Report 
(Contact ID Event Code 401) is sent at the end of 
Exit Time when the system is armed in AWAY 
Mode.   
If an expanded format is selected, this code is used as 
the Expansion Code and the user number that armed 
or disarmed the system follows in the same 
transmission. 
To enable Open and Close Reports in STAY 
Mode: 
Select Option 2 in Location 178 (refer to Section 12.2 
Dialer Options 2 
on page 53). To enable Open and 
Close Reports only after a previous alarm, select 
Option 1 in Location 178. 
 
 
 
 
If Open and Close Reports are not 
required, program Locations 401 and 402 
as 0. 
A partitioned ICP-CC488 Control Panel 
sends Open/Close Reports with Contact 
ID Event Code 402. 
15.14  Open/Close Reporting Options 
Location
403 
No Open/Close Reports allowed 
Report to Receiver 1 
Report to Receiver 2 
Report to both Receiver 1 and Receiver 2 
Report to Receiver 2 only if Receiver 1 fails 
Location 403 is set by default to report only to 
Receiver 1. You can select whether Open and Close 
Reports are sent to Receiver 1, Receiver 2, or both, 
Receiver 2 only when Receiver 1 fails, or no 
reporting. 
15.15  Codepad Duress Report 
Location
404 
Default 
A Duress Report (Contact ID Event Code 121) is 
sent to the base station receiver when 9 is added to 
the end of any valid User Code used to disarm the 
system. This alarm is always silent. A Duress Alarm 
can be activated during Exit Time. In other words, if 
the system is armed and then disarmed by adding 9 
to the end of the User Code before Exit Time 
expires, a Codepad Duress Report is transmitted. 
Adding 9 to the end of a User Code when arming the 
system does not cause a Duress Alarm.  
If you want a 3 to activate a Codepad Duress Alarm 
instead of 9, select Option 2 in Location 498 (refer to 
Section 18.7 Consumer Options 3 on page 83). 
 
Restore Reports are not sent for this 
event.  
If Codepad Duress Reports are not 
required, program Location 404 as 0. 
15.16 Codepad Panic Report 
Location
405 to 406 
 Location 
Default 
Tens digit 
405 
Units digit 
406 15 
A Panic Alarm Report (Contact ID Event Code 120) 
is sent to the base station receiver when a user 
presses either [1] and [3] or [STAY] and [AWAY] at 
the same time. A Panic Alarm is audible, but you can 
program the alarm as silent by selecting Option 1 in 
Location 493 (refer to Section 18.2 System Options 2 on 
page 81).