Mitsubishi Electronics MR-J2S- CL User Manual

Page of 337
4 -  30
4. OPERATION
(b) Using the input signals for setting
Set the pulse generator multiplication 1 (TP0) and pulse generator multiplication 2 (TP1) to the
input signals in "Device setting" on the Servo Configuration Software (refer to Chapter 6).
Pulse generator multiplication 2
(across TP1)
Pulse generator multiplication 1
(across TP0)
Multiplication ratio of servo motor
rotation to manual pulse generator
rotation
Moving distance
0
0
Parameter No.1 setting valid
0
1
1 time
1[ m]
1
0
10 times
10[ m]
1
1
100 times
100[ m]
Note. 0: OFF
 1: ON
(4) Operation
Turn the manual pulse generator to rotate the servo motor. For the rotation direction of servo motor,
refer to (2) in this section.