Wiring
Refer to the figure below and the interconnection diagram at the back of this manual to connect 
cables.
Connector
*1: Attach a crimp-on lug (inner dia. 
φ4) for monitor unit side. Make the length of the ground wire 
as short as possible.
*2: Slide switch
•  ON (upward): Allow digital signal from external equipment to control on/off of the monitor unit.
•  OFF (downward): Set to OFF for analog RGB signal.
Note: Turn the slide switch off when you connect equipment to both the DVI and RGB ports.
*3: BRILL CTRL port
No use. Do not remove the sticker from the connector.
How to fix power cable
Fix the power cable with the cable clamp to prevent it from loosening.
FSV-84/84L
FSV-30/S-BB
FSV-24/S-BB
FCV-30
FCV-1200L/M
FSV-84/84L
FSV-30/S-BB
FSV-24/S-BB
FCV-30
FCV-1200L/M
FAR-21x7
FEA-2107
FCR-21x7
FAR-21x7
FEA-2107
FCR-21x7
FEA-2107
FCR-21x7
FEA-2107
FCR-21x7
The bottom of the rear of the monitor unit
RGB signal
3COX-2P-6C 
5 m/10 m (option)
RGB signal
3COX-2P-6C 
5 m/10 m (option)
RGB signal
3COX-2P-6C 
5 m/10 m (option)
Digital signal 
DVI-D/D S-LINK 
5 m (standard)/ 
10 m (option)
Digital signal 
DVI-D/D S-LINK 
5 m (standard)/ 
10 m (option)
Digital signal 
DVI-D/D S-LINK 
5 m (standard)/ 
10 m (option)
Composite 
signal cable
Composite 
signal cable
Composite 
signal cable
CCD camera
DVD recorder
CCD camera
DVD recorder
CCD camera
DVD recorder
BRILL CTRL 
port *
3
BRILL CTRL 
port *
3
BRILL CTRL 
port *
3
IV-8 sq 
(local supply) *
1
IV-8 sq 
(local supply) *
1
IV-8 sq 
(local supply) *
1
To ground 
terminal on hull
DPYC-1.5
(or equivalent)
DPYC-1.5
(or equivalent)
DPYC-1.5
(or equivalent)
100-230 VAC
Slide 
switch *
Slide 
switch *
Slide 
switch *
Power 
switch
Fuse
RS-232C cable 
(Max. 10 m)
RS-232C cable 
(Max. 10 m)
RS-232C cable 
(Max. 10 m)
DPYC-1.5
φ = 
11.7 mm
Armor
Sheath
Conductor
S = 1.5 mm
2
φ = 1.56 mm
Attach the Terminal Board Gear Cover 
again after connecting cables.
MU-190
Cable 
clamp
Length: 40 mm
Length: 60 mm
Local supply
Replace MU-201CE with MU-190 
Cut the connector of the power 
cable (15-565, supplied on the 
MU-201CE). Attach a crimp-on lug 
(supplied on the MU-190) to each 
cable core then connect the 
cables as in the figure at right.