CHAPTER 36: EXTERNAL BUS INTERFACE 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : EXTERNAL BUS INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
41 
5.9.  RDY Pin Access Cycle Extension Function 
This section shows the RDY pin access cycle extension function. 
The read and write strobe cycles can be extended even after the auto wait cycles have finished by inputting 
"0" to the RDY pin. 
This function can be enabled by the RDY pin for access to the corresponding area when setting AWR: 
RDYE to "1". 
Use this function by setting the auto wait cycles of the corresponding area to 2 or more. 
After the auto wait cycle has finished, the read and write strobe cycles are extended while "0" is input to 
RDY. If "1" is input to RDY after this, the read or write strobe cycle finishes in the next cycle. 
 
RDY Signal Input Specifications 
The input RDY signal adheres to the following specifications. 
· 
Input RDY=1 except when extending the auto wait cycles. 
· 
Begin inputting RDY=0 after checking that access to an area covered by auto wait cycle extension has 
started with ASX="L" and CSnX="L". 
· 
Start inputting RDY=0 before the auto wait cycle ends. It is prohibited to input RDY=0 after the auto 
wait cycles have ended. 
· 
Input RDY=1 after the required extension cycles have finished. 
 
Figure 5-8 RDY Timing Example 
 
 
 
 
1          2          3          4          5          6          7          8          9
 
0
 
1
 
0
 
cycle n
 
o
 
.
 
SYSCLK
 
ASX
 
R
 
D
 
Y
 
RDX
 
WRnX
 
(n=0,1)
 
CSnX
 
(n=0,1,2,3)
 
CSnX
 
(n=0,1,2,3)
 
RDX
 
WRn
 
X
 
(n=0,1)
 
Auto wait cycle
 
Auto wait cycle
 
Basic example when 
auto wait cycles 
set to 2 cycles
 
Example of extending 
wait cycles of basic 
example by 3 cycles 
using RDY
 
Extension cycles by RDY
 
MB91520 Series
MN705-00010-1v0-E