CHAPTER 39: RAMECC 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : RAMECC 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
23 
5.4.  Note 
This section explains note. 
A single bit error might be detected at the fault detection in three bits or more, and the correction operation 
not intended start. 
 
 
 