CHAPTER 40: MULTI-FUNCTION SERIAL INTERFACE 
 
 
8. Operation of I2C 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : MULTI-FUNCTION SERIAL INTERFACE 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
347 
Figure 8-15 Master Transmission Interrupt (1)-when FIFO is Disabled   
(SSR:DMA="0", IBCR:WSEL="0", IBSR:RSA="0") 
   
             S   Slave Address    W  ACK     Data       ACK    Data        ACK  Data        ACK  P or Sr 
                                        △                △                 △                △▲ 
                                        ①                ②                 ②                ③ 
S: Start condition 
W: Data direction bit (Write direction) 
P: Stop condition     
Sr: Repeated start condition 
: Interrupt because of INTE = "1" 
: Interrupt because of CNDE = "1" 
(1) An interrupt generated by slave address transmission + direction bit transmission +   
     acknowledgment reception 
      - Write INT = "0" after the transmission data is written to the TDR register 
(2) An interrupt generated by 1 byte transmission + acknowledgment reception 
      - Write INT = "0" after the transmission data is written to the TDR register 
(3) An interrupt generated by 1 byte transmission + acknowledgment reception 
      - Set MSS = "0" or MSS = "1" and SCC = "1" 
    *: The TDRE bit is "1" upon the generation of the interrupt flag (INT) 
 
 
 
Figure 8-16 Master Transmission Interrupt (2)-when FIFO is Disabled 
(SSR:DMA="0", IBCR:WSEL="1", IBSR:RSA="0", ACK Response) 
  
             S    Slave Address  W   ACK     Data       ACK    Data       ACK  Data         ACK  P or Sr 
                                        △            △                 △               △     ▲ 
                                        ①            ②                 ②               ③ 
S: Start condition 
W: Data direction bit (Write direction) 
P: Stop condition     
Sr: Repeated start condition 
: Interrupt because of INTE = "1" 
: Interrupt because of CNDE = "1" 
(1) An interrupt generated by slave address transmission + direction bit transmission + 
     acknowledgment reception 
      - Write INT = "0" after the transmission data is written to the TDR register 
(2) An interrupt generated by 1 byte transmission 
      - Write INT = "0" after the transmission data is written to the TDR register 
(3) An interrupt generated by 1 byte transmission 
      - Set MSS = "0" or MSS = "1" and SCC = "1" 
   *: The TDRE bit is "1" upon the generation of the interrupt flag (INT) 
 
 
 
 
MB91520 Series
MN705-00010-1v0-E