Fujitsu FR81S User Manual

Page of 2342
CHAPTER 51: TIMING PROTECTION UNIT 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : TIMING PROTECTION UNIT 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
19 
[bit1, bit0] PS[1:0] (Individual Prescaler) : Timer prescaler setting 
The prescaler value of each timer is set. The output of global prescaler is input to each timer, and the input 
is divided and it is used as operating clock of each timer. 
PS[1:0] 
Prescaler 
00 
1/1 
01 
1/2 
10 
1/4 
11 
1/16 
 
 
 
MB91520 Series