43
Figure 5-14 Compare One-shot Operation (2 / 2)
(for OUTL=0)
TOUT
(for OUTL=0)
Count clock
Count clock
Underflow
Underflow
Activation
Activation
Activation trigger
waiting
waiting
Activation trigger
waiting
waiting
Activation trigger
waiting
waiting
1 count
1 count
Register reloaded
Register reloaded
trigger waiting
•
Sets TMRLRB = TMRLRA
TMRLRA
TMRLRA
TMRLRA+1
TMRLRA+1
Compare one-shot function (TMRLRB=TMRLRA)
•
Sets TMRLRB = 0
TMRLRA
TMRLRA
TMRLRA+1
TMRLRA+1
H
L
Compare one-shot function (TMRLRB="0")
by timer
by timer
trigger
trigger
Activation
trigger waiting
Activation
TOUT
When the register relation is as described above, TMR will become smaller than TMRLRB
after 1 count. Thus the TOUT output is the L level for 1 down count and then the H level until
an underflow occurs. When an underflow occurs, the timer will turn into the activation trigger
waiting state and the TOUT output will be the L level (for OUTL="0").
after 1 count. Thus the TOUT output is the L level for 1 down count and then the H level until
an underflow occurs. When an underflow occurs, the timer will turn into the activation trigger
waiting state and the TOUT output will be the L level (for OUTL="0").
When the register relation is as described above, the TOUT output is the L level between
down count start and an underflow occurrence because TMR will not become smaller than
TMRLRB. The level will remain to be L even when an underflow occurs (for OUTL="0").
down count start and an underflow occurrence because TMR will not become smaller than
TMRLRB. The level will remain to be L even when an underflow occurs (for OUTL="0").
MB91520 Series
MN705-00010-1v0-E
770