 DW6000 Troubleshooting
Check Network
Operations Center (NOC)
connectivity
Use the 
Connectivity Test
 link to check connectivity to the DIRECWAY 
Network Operations Center (NOC).
Note:
You may want to open a second browser window to be able to access the 
help page while conducting the Connectivity Test.
1. Click on 
Connectivity Test
 on the left hand side of the 
System Control 
Center
. A screen with a Start Test button appears. See Figure 21.
2. Click Start Test. A message will appear, informing you if the test was 
successful.
3. If the connectivity test succeeds but you still cannot surf the Internet, try 
pinging the Router Address from your computer. Ping is a basic Internet 
program that lets you verify that a particular IP address exists and can 
accept requests. Ping is used diagnostically to ensure that a host computer 
you are trying to reach is actually operating. Ping operates by sending a 
packet to a designated address and waiting for a response. Windows and 
MacIntosh operating systems both let you use ping.
a. At the Control Center, click on the 
System Info
 indicator. The System 
Info screen appears.
b. From the 
DW6000 Information
 box, record the router address.
c. In Windows, go to 
Start
 Run
. The Run box appears.
d. Type 
command
 in the 
Open
 field and click OK. The 
Command 
window 
e. At the prompt, type 
ping 
followed by a space and the router address and 
press E
NTER
. For example, if the router address is 100.100.100.100, type 
ping 100.100.100.100 
and press E
NTER
. If the ping is successful, 
the message in Figure 22 appears. If it fails, the message will show the 
packets were lost; timeout messages will probably also appear. See 
Figure 23.
f. Close the window to end the Command session. 
If pinging the Router Address succeeds but you still cannot surf the Internet, 
skip to the Internet Connectivity test below.
If pinging the Router Address fails, the default gateway address is probably 
not set correctly in the computer’s operating system settings. The default 
gateway address should be the DW6000 IP address as received during 
commissioning and displayed in the System Information DW6000 Info box 
in the IP address line. Fix this in the computer's operating system settings. 
See Appendix A – Typical operating system settings, on page 45. The
repeat the sequence above. 
If the tests still fail, power cycle the DW6000 by unplugging the power cord 
from the power strip or surge protector, waiting 10 seconds, and plugging it 
back in. If you still can’t surf the Internet, call your service provider.