Panasonic PT-AX200E User Manual

Page of 54
40 - 
E
NGLISH
Maintenance
TEMP and LAMP Indicators
If a problem should occur with the projector, the LAMP and/or TEMP 
indicators will inform you. Manage the indicated problems as follow.
1. Confirm the status of all indicators and projector, and switch off 
the projector in proper way.
2. Find out the cause of the problem by status of the LAMP and/or 
TEMP indicators.
3. Follow the following instruction for each indication and solve the 
problem.
4. Turn on the projector in the correct way and confirm the 
indicator is not indicating a problem any longer.
J
LAMP indicator
J
TEMP indicator
Managing the indicated problems
NOTE:
• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorised Service Centre.
Indicator
 
Illuminating red
 
Flashing red
Problem
LAMP RUNTIME has 
reached 1 800 hours.
The lamp circuit failure, abnormal function or lamp unit is damaged.
Cause
The lamp unit will run 
out soon and needs to 
be replaced.
The MAIN POWER is 
switched on again 
before the lamp unit is 
cooled enough.
The lamp circuit failure, 
abnormal function.
The lamp unit is 
damaged.
Remedy
Let the lamp unit cool 
down and turn on the 
MAIN POWER.
Contact an Authorised 
Service Centre.
Indicator
 
Illuminating red and still projecting
 
Flashing red and the POWER button is turned off
Problem
The temperature inside and/or outside the projector is abnormally high.
Cause
The ventilation openings are 
covered.
The room temperature is too 
high.
The air filter is excessively dirty 
and the ventilation is poor.
Remedy
Remove the object(s) from the 
ventilation openings or clear 
around the projector.
Reinstall the projector in 
temperature controlled place. 
See page 48.
Replace the air filter in the 
proper method. See page 41.
POWER LAMP TEMP