"B-VENT" FIREPLACES
Model
Conversion Kit Model 
(Part Number)
BVD34FP3 SERIES
BVCK34P (19160)
BVD36FP3 SERIES
BVCK36P (19161)
BVP42FP3 SERIES
BVCK42P (19162)
FOR CONVERSION TO LIQUEFIED PETROLEUM GAS
WARNING
This conversion kit is to be installed by an Empire Comfort 
Systems, Inc. dealer (or other qualified agency
1
)* in accordance 
with  the  manufacturer's  instructions  and  all  codes  and 
requirements of the authority having jurisdiction. Failure to 
follow instructions could result in serious injury or property 
damage. The qualified agency performing this work assumes 
responsibility for this conversion.
1
 National Fuel Gas Code Z223.1 (Latest Edition), Natural Gas and Propane 
Installation Code, CSA B149.1
*The term "qualified agency" means any individual, firm, corporation or 
company which either in person or through a representative is engaged in 
and is responsible for (a) the installation of gas piping or (b) the connection, 
installation repair, or servicing of equipment, who is experienced in such 
work, familiar with all precautions required, and has complied with all the 
requirements of the authority having jurisdiction. 
V
E
N
T
PI
LO
T
IN
CHECK SAFETY SHUTDOWN PERFORMANCE
WARNING
Perform the safety shutdown test any time work is done 
on a gas system to avoid the possibility of fire or explosion 
with property damage, personal injury or loss of life.
SAFETY SHUTDOWN SYSTEM
Continuous Ignition Systems
1. Place gas control knob in Pilot position. Main burner should go 
off and pilot should remain lit.
2. Extinguish  pilot  flame.  Pilot  gas  flow  should  stop  within  3 
minutes. Safety shutoff of pilot gas proves complete shutdown 
since safety shutoff valve blocks flow of gas to main burner and 
pilot.
3. Wait 5 minutes, then relight pilot burner and operate system 
through one complete cycle to make sure all controls operate 
properly.
PARTS LIST
Conversion Kit 
Model
BVCK34P
BVCK36P
BVCK42P
Part 
Description
Kit No. 19160 Kit No. 19161 Kit No. 19162 Quantity 
Supplied
Fireplace
BVD34FP3 
SERIES
BVD36FP3 
SERIES
BVP42FP3 
SERIES
Pilot Orifice
#35 (R-7658)
#35 (R-7658)
#35 (R-7658)
1
Main Burner 
Orifice
P-289
1.35mm
P-208
1.45mm
P-250
1.65mm
1
Dexen 10" w.c. 
Regulator
R-7548
R-7548
R-7548
1
Gas Conversion 
Label
2139
2139
2139
1
Gas input for "B-Vent" fireplace converted to Liquefied 
Petroleum Gas:
BVD34FP3 SERIES
21,000 BTU per hour
BVD36FP3 SERIES
25,000 BTU per hour
BVP42FP3 SERIES
30,000 BTU per hour
The "B-Vent" fireplace when converted to LP Gas will have manifold 
pressure of 10.0" w.c. at the valve outlet with the inlet pressure to 
the valve from a minimum of 10.8" w.c., for the purpose of input 
adjustment, to a maximum of 14.0" w.c.
INSTRUCTIONS FOR CONVERSION
1.  If the fireplace is installed, turn off gas and electric supply before 
making the gas conversion.
2.  Identify  the  fireplace  model  to  be  converted,  and  read  all 
instruction steps prior to converting the gas valve.
3.  Remove all logs from the burner assembly.
4.  Open the sliding valve access door.
5.  Depress and turn the gas cock dial to the "OFF" position.
VALVE CONVERSION
6.  Remove two (2) screws, regulator, and gasket from gas valve 
control body.
7.  Install the new gasket, regulator, and gasket from gas valve control 
body.
BURNER ORIFICE CONVERSION - Tube style burners
8a.  On models BVD(34,36)FP3 series fireplaces, you will have a 
U-shaped burner tube. To gain access to the main orifice, simply 
bend over the small retainer tab located at the front right end of 
the tube using pliers.
9a.  Remove the 1/4" long screw from the air shutter at the left end 
of the tube.
10a. Pull up on the back of the burner and rotate forward to gain access 
to the main orifice. Remove the orifice and replace with the LP 
orifice designated in the orifice reference chart. Secure the new 
orifice.
11a. Pivot the burner tube back down in its original position mating 
with the air shutter, and reinstall the 1/4" long screw. Set the air 
shutter opening in accordance with the dimension shown in the 
reference chart for the appropriate model fireplace.
STANDING PILOT PROPANE/LP GAS CONVERSION