Vulcan-Hart BVD36FP52(F,L)N-1 User Manual

Page of 40
Page 20
19400-3-0406
With proper installation and maintenance, your new  Gas Fireplace will provide years of trouble-free service. If you do experi-
ence a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of 
problems and the corrective action to be taken.
1.  Spark ignitor will not light pilot after repeated triggering 
of piezo ignitor button.
a.  Defective ignitor (no spark electrode) 
  —Check for spark at electrode and pilot; if no spark and 
electrode wire is properly connected, replace ignitor.
b.  No gas or low gas pressure.
  —Check remote shut off valves from fireplace. Usually 
there is a valve near the main. There can be more than one 
(1) valve between the fireplace and main.
  —Low pressure can be caused by a variety of situations 
such as a bent line, too narrow diameter of pipe, or low line 
pressure. Consult with plumber or gas supplier.
c.  No LP in tank. 
  —Check LP (propane) tank. Refill tank.
2.  Pilot  will  not  stay  lit  after  carefully  following  lighting 
instructions.
a.  Defective thermopile.
  —Check that pilot flame impinges on thermopile. Clean 
and/or adjust pilot for maximum flame impingement.
  —Ensure the thermopile connections at the gas valve are 
fully tight. 
3.  Pilot burning, no gas to burner, valve knob “ON.”
a.  Wall switch, remote control or wires defective.
  —Check wires for proper connections. Place jumper wires 
across  terminal  at  switch.  If  burner  comes  on,  replace 
defective switch. If OK, place jumper wires across switch 
wires at gas valve-if burner comes on, wires are faulty or 
connections are bad.
b.  Thermopile may not be generating sufficient millivolts.
  —If the pilot flame is not close enough physically to the 
thermopile, adjust the pilot flame.
  —Be sure the wire connections from the thermopile at the 
gas valve terminals are tight and the thermopile is fully 
inserted into the pilot bracket.
  —Check the thermopile with a millivolt meter. Take the 
reading at TH-TP & TP terminals of the gas valve. The 
meter should read 350 millivolts minimum, while holding 
the valve knob depressed in the PILOT position, with the 
pilot lit, and the switch in the OFF position. Replace the 
faulty  thermopile  if  the  reading  is  below  the  specified 
minimum. 
  —With  the  pilot  in  the  ON  position,  disconnect  the 
thermopile  leads  from  the  valve.  Take  a  reading  at  the 
thermopile  leads.  The  reading  should  be  350  millivolts 
minimum. Replace the thermopile if the reading is below 
the minimum.
c.  Defective valve.
  —Turn valve knob to ON. Place Remote/Off/On switch to 
ON. Check with millivolt meter at thermopile terminals. 
Millivolt meter should read greater than 200 millivolts. If 
the reading is okay and the main burner does not ignite, 
replace the gas valve.
d.  Plugged main burner orifice.
  —Check main burner orifice for blockage and remove.
4.  Frequent pilot outage problem.
a.  Pilot flame may be too high or too low, or blowing (high), 
causing pilot safety to drop out.
  —Clean and adjust flame for maximum flame impingement 
on  the  thermocouple.  Follow  lighting  instructions 
carefully.
5.  The pilot and main burner extinguish while in operation.
a.  No LP (Propane) in tank.
Check LP (Propane) tank. Refill fuel tank.
b.  Bad thermopile or thermocouple.
  —Replace if necessary.
c.  Improper vent cap installation.
  —Check for proper installation and freedom from debris 
or blockage.
6.  (Glass) Sooting
a.  Flame impingement on logs. 
  —Check and adjust log position. Contact Empire Comfort 
Systems, Inc.
b.  Debris around throat of main burner.
  —Inspect the opening at the base of the main burner. It is 
imperative that NO material be placed in this opening.
STANDING PILOT TROUBLESHOOTING