Paradyne CSU User Manual

Page of 470
B. SNMP MIBs and Traps, and RMON Alarm Defaults
9128-A2-GB20-80
September 2002
B-11
Table B-6.
linkUp and linkDown Variable-Bindings (1 of 2) 
Interface
Variable-Bindings
Possible Cause
Physical Sublayer
T1 Network, 
DSX-1, 
PRI
(Supported by the 
media-specific DS1 
MIB.)
„
ifIndex (RFC 1573)
„
ifAdminStatus (RFC 
1573)
„
ifOperStatus (RFC 1573)
„
devLastTrapString 
(devHealthAndStatus.-
mib)
„
linkDown – One or more alarm 
conditions are active on the 
interface.
Alarm conditions include:
– Loss of Signal (LOS) or 
far-end loss of signal
– Out of Frame (OOF)
– Alarm Indication Signal 
(AIS)
– Excessive Error Rate (EER)
– Yellow Alarm 
Strings: 
‘$ifString down.’ No alarms 
exist. (e.g., ‘Network T1 down 
due to yellow alarm.’ )
‘$ifString administratively 
shutdown.’ (Due to an 
intentional shutdown.)
„
linkUp – No alarms on the 
interface.
String: 
‘$ifString up.’
Synchronous Data 
Port
(Supported by the 
media-specific 
RS232-like MIB.)
„
ifIndex (RFC 1573)
„
ifAdminStatus 
(RFC 1573)
„
ifOperStatus (RFC 1573)
„
devLastTrapString 
(devHealthAndStatus.-
mib)
„
linkDown – One or more alarm 
conditions are active on the 
port.
Alarm conditions include:
– DTR off
– RTS off
– ‘ ’ – Not DTR or RTS, but 
link is down.
String: 
‘$ifString $alarmString down.’ 
(e.g., ‘Sync Data Port S01P1 
DTR and RTS down.’)
‘$ifString administratively 
shutdown.’ (Due to an 
intentional shutdown.)
„
linkUp – No alarms on the port.
String: 
‘$ifString up.’
1
The DTR alarm condition will only generate a linkUp/ linkDown trap if the DTE 
supports the DTR lead state.
2
The RTS alarm condition will only generate a linkUp/ linkDown trap if the DTE 
supports the RTS lead state.
3
If the LMI Protocol is not configured, a linkUp/linkDown trap is based solely upon 
whether the interface is enabled or disabled.