Intermec 2430 User Guide

Page of 374
Chapter 6—Configuration Command Reference 
222 
Trakker Antares 2400 Family System Manual 
 
Bar Codes:  To disable the preamble, scan this bar code: 
Disable Preamble 
*$+AD* 
*$+AD* 
 
Or:  To set the preamble to an ASCII character string: 
 
Note: To set this command using the bar code labels from the “Full ASCII 
Bar Code Chart” on page 284, you must configure the terminal to use 
Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. 
Scan this bar code: 
  Enter Accumulate Mode / Set Preamble 
 
*+/$+AD* 
 *+/$+AD* 
Scan a value for data from the “Full ASCII Bar Code Chart” on page 
284. The preamble can be from 1 to 25 characters. 
Scan this bar code: 
  Exit Accumulate Mode 
 
*-/* 
 *-/* 
 
Example:  You want to set a preamble that includes quotation marks. Enter the 
preamble by scanning this full ASCII bar code label: 
Set Preamble to “B” 
*/D/KAD/B/B/BB/B/B/B* 
*$+AD"""B"""* 
You must enclose the data within quotation marks and precede each 
quotation mark with another quotation mark so that the quotation marks 
are not treated as the end of the data. 
Radio MAC Address 
 
Terminals:  2415, 2425, 2435, 2455, 2475, and 2485/6. 
 
Description:  Returns the MAC address of the radio that is installed in the RF terminal. 
You can only use this read-only command in an application to return the 
value (MAC address) to the application.  
 
Syntax: RI 
 
Default: None