Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
5-15
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 5      Repairing and Maintaining the 8112 Server
  Replacing a power supply unit fan filter
Step 3
Pull the fan filter’s frame up at a slight angle to remove it, sliding it in between the power supply unit 
and the power supply unit handle.
Step 4
Remove the power supply unit fan filter from its frame.
Installing a new power supply unit fan filter
Step 1
Slide the new power supply unit fan filter into the power supply unit fan filter frame.
Step 2
Place the new power supply unit fan filter frame between the power supply unit and the power supply 
unit handle.
Note
The correct orientation is when the metal tab on the new power supply unit fan filter frame is in 
the top left corner. See 
Step 3
Gently push the new power supply unit fan filter frame into place. There is no lock position, just make 
sure the new power supply unit fan filter frame stays in place. You do not need to use much force.
Step 4
Attach the power cable to the back of the server.
Step 5
Power up the server. Refer to the 
Testing the power supply unit fan filter
Step 1
If not already connected, access the CLI by following the procedures in the 
 and 
Step 2
Login as a technician. The tech$ prompt appears.
Step 3
Turn on terminal logging. For information on logging, see 
.
Step 4
Type 
hwconfig
 and press Enter
 appears.