Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
5-31
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 5      Repairing and Maintaining the 8112 Server
  Replacing T1 Smart Blades or Smart Blades
Removing an old T1 Smart Blade or Smart Blade transition module
Step 1
Locate the T1 Smart Blade or Smart Blade card’s corresponding transition module in the back of the 
server.
Step 2
Loosen the T1 Smart Blade or Smart Blade transition module’s two captive screws at the top and bottom 
of the panel. See 
Step 3
Press the ejector levers outward. This partially unseats the T1 Smart Blade or Smart Blade transition 
module from the backplane connectors. See 
Step 4
Pull the T1 Smart Blade or Smart Blade transition module from the chassis by pressing the ejector levers 
outward and pulling the transition module out. See 
.
Installing a new T1 Smart Blade or Smart Blade transition module
Step 1
Ensure that the system is powered down. If you are installing a new T1 Smart Blade or Smart Blade 
transition module immediately after removing an old one, the system should still be powered down. 
Otherwise, follow the steps in the 
.
Step 2
Press the ejector levers outward. See 
.
Step 3
Holding the T1 Smart Blade or Smart Blade transition module by the levers, partially insert the transition 
module into the slot, about half way.
Step 4
Verify that the T1 Smart Blade or Smart Blade transition module is properly seated in the guides on the 
top and bottom. If not, remove the transition module and try again.
Step 5
Pushing gently and firmly on the T1 Smart Blade or Smart Blade transition module’s face plate, slide the 
transition module into the slot until you encounter significant resistance. At this point, the levers should 
be in contact with the chassis rails so they will grab when pushed inward.
Step 6
Use the ejector levers to seat the T1 Smart Blade or Smart Blade transition module in the slot by closing 
the levers toward one another until they are in the horizontal locked position. See 
Step 7
Secure the T1 Smart Blade or Smart Blade transition module by tightening the captive screws on the top 
and bottom of the panel. See 
.
Step 8
Verify that any empty slots have covers on them.
Warning
An empty slot that is uncovered can result in a destructive hardware failure.
Step 9
Attach the power cable to the back of the server.
Step 10
Power up the server. Refer to the