Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
5-32
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 5      Repairing and Maintaining the 8112 Server
  Replacing a Multi Access Blade
Testing a T1 Smart Blade or Smart Blade card and transition module
Step 1
Verify the T1 Smart Blade or Smart Blade card’s ejector levers are locked. If the LED on the bottom of 
the card is blue, the card is not locked. If the card is not locked, see the 
 and reseat the card.
Step 2
Verify the T1 Smart Blade or Smart Blade transition module’s ejector levers are locked. If the LED on 
the bottom of the T1 Smart Blade or Smart Blade card is blue, the transition module is not locked. If the 
transition module is not locked, see the 
 and reseat 
the transition module.
Step 3
Test the installation by following the procedure in the 
.
Replacing a Multi Access Blade
This section provides instructions on how to replace a Multi Access Blade’s card and transition module.
Warning
Handling these cards can result in static damage. Use an anti-static wrist strap, static-dissipating 
work surface, and anti-static bags when handling and storing these cards.
Note
Each Multi Access Blade card has a transition module in the same slot in the back of the server. 
Whenever a Multi Access Blade card is replaced, its corresponding transition module must also be 
replaced.
Removing an old Multi Access Blade card
Step 1
Verify all steps in the 
 have been completed.
Step 2
Verify which Multi Access Blade card needs replacing. Locate the two red plastic latches on the top and 
bottom of the card within each black plastic handle.
Step 3
Press on both red latches and release them.
Step 4
Lift both of the black plastic handles to unseat the Multi Access Blade card.
Step 5
Gently pull the Multi Access Blade card out of the chassis.
Installing a new Multi Access Blade card
Step 1
Ensure that the system is powered down. If you are installing a new Multi Access Blade card 
immediately after removing an old one, the system should still be powered down. Otherwise, follow the 
steps in the 
.
Step 2
Verify which slot number the new Multi Access Blade card is going into.