Chapter 5      Repairing and Maintaining the 8106 Server
  Replacing T1 Smart Blades or Smart Blades
Figure 5-13 Removing a T1 Smart Blade Card and Transition Module
Installing a new T1 Smart Blade or Smart Blade card
Step 1
Ensure that the system is powered down. If you are installing a new T1 Smart Blade or Smart Blade card 
immediately after removing an old one, the system should still be powered down. Otherwise, follow the 
steps in the 
.
Step 2
Press the ejector levers outward. See 
Step 3
Holding the T1 Smart Blade or Smart Blade card by the levers, partially insert the card into the slot, 
about half way.
Step 4
Verify that the T1 Smart Blade or Smart Blade card is properly seated in the guides on the left and right. 
If not, remove the card and try again.
Step 5
Pushing gently and firmly on the card’s face plate, slide the card into the slot until you encounter 
significant resistance. At this point, the levers should be in contact with the chassis rails so they will grab 
when pushed inward.
Step 6
Use the ejector levers to seat the T1 Smart Blade or Smart Blade card in the slot by closing the levers 
toward one another until they are in the locked position. See 
Step 7
Secure the T1 Smart Blade or Smart Blade card by tightening the captive screws on the left and right of 
the panel. See 
.