Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual
3-21
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8106)
78-16411-01
Chapter 3 Installing the 8106 Server
Connecting the system cables
Figure 3-14 Breakout Box, Back View
Step 6
Connect the other end of the first trunk card cable assembly (50-pin Amphenol cable) into the Multi
Access Blade transition module by securing the screws on both ends. The connector on the right of the
Multi Access Blade transition module is for spans 1-8 and the connector on the left of the Multi Access
Blade transition module is for spans 9-16. The first cable should go into the connector on the right. See
Access Blade transition module by securing the screws on both ends. The connector on the right of the
Multi Access Blade transition module is for spans 1-8 and the connector on the left of the Multi Access
Blade transition module is for spans 9-16. The first cable should go into the connector on the right. See
Figure 3-15 Multi Access Blade Transition Module
Step 7
Repeat steps 5 and 6 for the second trunk card cable assembly (50-pin Amphenol cable). The second
cable should go into the connectors on the left of the breakout box and on the left of the Multi Access
Blade.
cable should go into the connectors on the left of the breakout box and on the left of the Multi Access
Blade.
illustrates the 8106 server’s connections from the back of the server. This configuration
supports 480 E1 ports with one Multi Access Blade card MA-16.
Figure 3-16 Back of Server (E1 with 1 MA-16)
illustrates the 8106 server’s connections from the back of the server. This configuration
supports 368 T1 PRI ports with one Multi Access Blade card MA-16.