Cisco Cisco Broadband Access Center for Cable 4.0 Maintenance Manual
7
Supported Syslogs and Traps in Cisco Broadband Access Center 4.0 and 4.0.1
OL-22203-01
Syslog Alerts and Messages
Watchdog Alerts
Whenever the process watchdog sends a syslog alert, you can find error details (if any) in the
BPR_DATA/agent/logs/agent_console.log file and the log files corresponding to the specific component
mentioned in the alert (if any). For example, if you receive an alert similar to The rdu unexpectedly
terminated, you would check the RDU server log file (BPR_DATA/rdu/logs/rdu.log) for additional
information.
BPR_DATA/agent/logs/agent_console.log file and the log files corresponding to the specific component
mentioned in the alert (if any). For example, if you receive an alert similar to The rdu unexpectedly
terminated, you would check the RDU server log file (BPR_DATA/rdu/logs/rdu.log) for additional
information.
lists the process watchdog alerts:
Table 4
Process Watchdog Alerts
The [component] variable presented in the process watchdog alerts list shown in
represents any
of these component values:
•
rdu
•
dpe
•
tomcat
•
cli
•
snmpAgent
•
kdc
Alert
Description
AGENT-3-9001: Failed to start the [component]
Indicates that the watchdog has failed to start the specified
component.
component.
AGENT-3-9002: The [component] unexpectedly terminated
Indicates that the specified component, monitored by the
process watchdog, has unexpectedly failed.
process watchdog, has unexpectedly failed.
AGENT-6-9004: The [component] has started
Generated any time a component is successfully started by
the process watchdog. This message is for informational
purposes only.
the process watchdog. This message is for informational
purposes only.
AGENT-6-9005: The [component] has stopped
Generated any time a component is successfully stopped
through the process watchdog. This message is for
informational purposes only.
through the process watchdog. This message is for
informational purposes only.
AGENT-3-9003: Failed to stop the [component]
Indicates that a component did not stop when the process
watchdog attempted to stop it.
watchdog attempted to stop it.
AGENT-3-9003:
Failed to create listener thread;
[error no]Failed to close listen socket;
[error no] Failed to cancel listen thread, and so on
Failed to create listener thread;
[error no]Failed to close listen socket;
[error no] Failed to cancel listen thread, and so on
Indicates errors that are not defined in other alert messages.