Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 15
 
10 
 
 
6  Verify the Forward Path RF performance for each port. Reference table below 
for standard configurations and RF Insertion Locations. 
 
FCM 
Type 
RX Cable RF Insert 
Node Port/Cable Connection 
Physical Location 
Port 1 
Port 2/3 
Port 4 
Port 5/6 
1x4 
O   O    O    1 
2x4 
4    O    O    1 
4x4 
4     3     2    1 
 
Note:  
 
Node Port/Cable Connection” number corresponds to the “Rx Cable 
RF Insert” position when testing a specific port. 
 
Additional FCM signal routes are defined in Cisco 1.2 GHz GS7000 Node 
Installation and Operation Guide
.  
 
Reverse Path RF Verification 
1  Install the RF module into the test GS7000 Node housing. 
2  Attach a network analyzer RF Source cable to Node Output port of the RF 
Amp module. 
3  Connect the cable adapter (part number GS7K-SPLKT-CBL) from the 
appropriate transmitter cable connector to the stealth meter or analyzer receive 
port. 
4  Note that the Amplifier gain will be approximately 0dB in this configuration. 
5  Verify the Reverse Path RF performance for each port. Reference table below for 
standard RCM configurations and RF output locations. 
 
RCM 
Type 
TX Cable RF Out 
Node Port/Cable Connections 
Physical Location 
Port 1 
Port 2/3 
Port 4 
Port 5/6 
4x1 
1    O    O   O 
4x2 
1    O     3   O 
4x4 
1     2     3    4 
 
Note:  
 
Node Port/Cable Connection” number corresponds to the “Tx Cable 
RF Out” position when testing a specific port. 
 
Additional RCM signal routes are defined Cisco 1.2 GHz GS7000 Node 
Installation and Operation Guide
.