To Re-install the Upgraded RF Amp Module 
1  Change the split indicator information on the cover to reflect the new split 
configuration. To do this, either move the adhesive dot to the proper designation 
OR remove the dot and use a permanent marker to designate the new 
configuration. 
2  Insert the upgraded RF amplifier module into the housing. 
3  Secure the amplifier module to the housing by tightening the seven module 
retainer screws with a screwdriver from 6 in-lb to 9 in-lb (0.7 Nm to 1.0 Nm). 
Note the tightening sequence which is marked on the amplifier cover. Repeat 
sequence to assure proper installation. 
4  Inspect the housing gasket and all mating surfaces. Wipe off any excess dirt and 
debris. 
5  Close the housing and finger-tighten all closure bolts. 
6  Use a torque wrench with a ½-inch socket to tighten each closure bolt from 5 ft-lb 
to 12 ft-lb (6.8 Nm to 16.3 Nm). 
7  Follow the numbered tightening sequence to tighten the closure bolts. 
 
 
Note: For additional details as needed, see RF Amplifier Assembly 
Replacement Procedure 
in Cisco 1.2 GHz GS7000 Node  Installation and Operation 
Guide
.