Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 15
 
 
 
 
Initial Steps
 
This section describes the steps for opening the node housing. 
 
Opening the Housing 
Open the housing as follows: 
1  Loosen the bolts securing the lid to the base (8 places). 
2  Carefully open the lid to allow access to the inside of the housing. 
3  Inspect gaskets on the cover flange. Make sure the gaskets are clean and free of 
any debris.  Prior to closing the node the environmental (black) gasket should be 
re-lubricated with silicon. 
4  Replace any gaskets showing signs of damage (cracked, twisted, pinched, or 
dry)  with new, silicon-lubricated gaskets. 
 
 
Upgrading the RF Split in the GS7000 Node
 
Note:  This  upgrade  procedure  can  be  used  in  the  field  or  to  reduce  network 
downtime you can use spare or in-stock RF module units to perform these steps 
to  upgrade  out-of-service  units.  Then  replace  in-service  RF  modules  with  the 
upgraded  RF  module  units.  Return  the  replaced  RF  modules  to  stock  so  that 
they can become the next  units for upgrade and swap procedures. 
 
 
 
 
CAUTION: 
To prevent electrostatic discharge (ESD) to electronic equipment, take ESD
precautions, including the use of an ESD wrist or ankle strap or an anti-static
mat.