power class negotiation. In some cases, the switch believes that the DMP can 
operate at a lower power class then the DMP actually requires, resulting in the DMP 
failing to complete boot up.   
Correction of this problem required a hardware change. USI executed an 
engineering change to the DMP 4310G in response to this issue.  DMP 4310Gs with 
serial numbers USI
1434
xxxx or greater have this engineering change and should 
not be subject to this issue. DMP 4310Gs with serial numbers less than 
USI
1434
xxxx may be subject to this issue, and should follow the suggested 
workaround. 
The serial number is located on the back and can be verified through visual 
inspection. The serial number is also remotely accessible as a MIB parameter, and 
can be located in the management dashboard under MIB Variables in the Status 
tab. Affected DMP’s can also be identified using the dashboard search option 
“Power over Ethernet DMP does not support PoE”. 
Workaround 
The correct workaround depends on the Cisco switch platform that the DMP is 
connected is enhanced Power over Ethernet (ePoE) capable. 
  ePoE Capable Platforms - If there is ample PoE power available in the switch’s 
power budget, apply the power inline static max 15401 interface-level 
command to each access switch port connected to a DMP-4310.   
The use of “power inline static max 15401” command requires “power inline port 
max 15401” be configured first.  
On an ePoE-capable switch platform, specifying a maximum power level greater 
than the 802.3af maximum of 15.4W has a side effect of causing the switch port 
to bypass the optional power class negotiation phase.   
The use of the static keyword is suggested in order to reserve the required 
power from the switch’s power budget at configuration time.  If for some reason 
the switch’s remaining power budget cannot accommodate the port’s configured 
power requirement, the port is placed into error disable state at point of 
configuration, rather than point of need. 
  Non-ePoE Capable Platforms – Because non-ePoE capable switch platforms 
cannot be configured to deliver more than the 802.3af maximum of 15.4W/port, 
the suggested workaround is to insert a PoE splitter between the switch port and 
the DMP 4310G. Generally, a PoE splitter is used to strip the PoE power from a 
PoE-capable switch port and provide it to a non-PoE capable device in lieu of its 
usual “power brick”. In this case, the PoE splitter is used to circumvent the DMP 
4310G PoE class negotiation issue, since the PoE splitter does not attempt to 
negotiate the PoE class with the switch and simply passes through the available 
power it receives over the cable run.  
The following PoE 12V splitter has been test to operate correctly with the DMP-
4310: