Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
4-3
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Chapter 4      Removal and Replacement Procedures
  Removing and Installing the AC-Input Power Supplies
Removing a 950 W or 1400 W AC-Input Power Supply
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use 
caution when servicing. 
Statement 1034
Note
In systems with redundant power supplies, you can replace the faulty supply while the system is 
operating.
Note
This procedure covers the removal of the power supply only. For information on removing the power 
entry module (PEM), see the 
Follow these steps to remove a power supply:
Step 1
Turn the power switch to the Off (0) position on the PEM for the power supply that you are removing. 
(
 shows the location of the AC-input PEMs on the Catalyst 6503 and Catalyst 6503-E switch 
chassis.) 
Step 2
Disconnect the power cord from the power source. Do not touch the metal prongs on the power cord 
when it is still connected to the PEM.
Step 3
Remove the power cord from the power connection on the PEM. Do not touch the metal prongs 
embedded in the PEM.
Step 4
Loosen the captive installation screws on the power supply. (See 
 for the Catalyst 6503 
and 6503-E switches.)
Step 5
Grasp the power supply handle with one hand, and slide the power supply part of the way out of the 
chassis. Place your other hand underneath the power supply, as shown in 
, and slide the power 
supply completely out of the chassis.
Step 6
If the power supply bay is to remain empty, install a blank power supply filler plate (Cisco 
part number 800-16727-01 for the Catalyst 6503 and Catalyst 6503-E switches) over the opening, and 
secure it with the captive installation screws.