Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
4-2
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Chapter 4      Removal and Replacement Procedures
  Removing and Installing the AC-Input Power Supplies
Removing and Installing the AC-Input Power Supplies
This section describes how to remove and install AC power supplies in the Catalyst 6500 series chassis. 
The AC-input power supplies have three different form factors, which are not interchangeable between 
the Catalyst 6500 series chassis. 
 lists the AC-input power supplies, the chassis that they are 
supported on, and the corresponding removal and replacement procedures.
Removing and Installing the 950 W and 1400 W AC-Input Power Supplies
This section describes how to remove and install the 950 W and 1400 W AC-input power supplies for 
the Catalyst 6503 and the Catalyst 6503-E switches. The section is divided into the following topics:
Note
The 950 W and 1400 W AC-input power supplies can be installed in the Catalyst 6503 and the 
Catalyst 6503-E switch chassis only.
Required Tools
You might need a flat-blade or number 2 Phillips-head screwdriver to loosen or tighten the captive 
installation screws on the power supply.
Table 4-1
Catalyst 6500 Series AC-Input Power Supplies Removal and Installation Procedures
Power Supply
Chassis Supported
Removal and Installation Procedure
950 W, 1400 W
Catalyst 6503, Catalyst 6503-E
2700 W
Catalyst 6504-E
1000 W, 1300 W, 
2500 W, 3000 W, 
4000 W, and 6000 W
Catalyst 6506, Catalyst 6506-E, 
Catalyst 6509, Catalyst 6509-E, 
Catalyst 6509-NEB, 
Catalyst 6509-NEB-A, 
Catalyst 6513