Cisco CATALYST 6509E 9 SLOT 15U CHASSIS NO POWER SUPPLY NO FAN TRAY Specification Guide

Page of 336
4-6
Catalyst 6500 Series Switches Installation Guide
OL-5781-04
Chapter 4      Removal and Replacement Procedures
  Removing and Installing the AC-Input Power Supplies
Step 6
Connect the other end of the power cord to an AC-input power source.
Caution
In a system with dual power supplies, connect each power supply to a separate input source. In case 
of a power source failure, the second source should still be available.
Step 7
Turn the PEM power switch to the On (|) position.
Step 8
Verify the power supply operation by checking that the power supply LEDs are in the following states:
INPUT OK LED is green
FAN OK LED is green
OUTPUT FAIL LED is not lit
If the LEDs indicate a power problem, see the 
troubleshooting information.
Removing and Installing the 2700 W AC-Input Power Supply
This section describes how to remove and install the 2700 W AC-input power supply in the 
Catalyst 6504-E switch. The section is divided into the following topics:
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution 
when servicing. 
Statement 1034
Note
In systems with redundant power supplies, you can replace the faulty supply while the system is 
operating.
Required Tools
You might need a flat-blade or number 2 Phillips-head screwdriver to loosen or tighten the captive 
installation screws on the power supply.