Senstar Corporation E7BA0300 User Manual

Page of 16
WGS Configuration
Rev A
Page 14
FlexZone Wireless Gate Sensor
2.
Select the GSM cfig tab.
3.
Select (check) the Enable checkbox.
4.
Specify the Locale (where the microwave will operate) FCC = North America; ETSI = Europe.
5.
If there is more than one FlexZone processor communicating with wireless gate sensors at 
this location, specify the RF channel for this processor.
6.
If Local control mode or Network Manager mode alarm reporting is being used for this 
processor, specify a relay to be activated if the receiver module fails (if desired).
If Remote control mode is being used for this processor, refer to the Network Manager online 
help and the Network Manager Interface application note (00DA0209) for details on 
configuring NM alarm reporting via the Silver Network.
7.
Select a GSM configuration tab.
8.
Enter the GSM’s serial number.
9.
Specify the GSM’s Supervision Mode.
10. If Local control mode or Network Manager mode alarm reporting is being used for this 
processor, specify a relay to be activated to report a GSM sensor alarm, a GSM supervision 
condition and a GSM Fault condition.
11. Download the configuration changes to the processor.
If the GSM will operate in conjunction with an auxiliary security device, configure the Local Bypass 
settings.
1.
Select the Alarm checkbox to mask GSM sensor alarms, select the Supervision checkbox to 
mask GSM supervision alarms when the auxiliary security device is active (in alarm).
2.
Specify the supervision scheme for the auxiliary input.
3.
Specify the supervision resistor value(s).
4.
Adjust the auxiliary input Noise Tolerance, Line Drop and Filter Window parameters, if 
required.
5.
If Local control mode or Network Manager mode alarm reporting is being used for this 
processor, specify a relay to be activated to report an auxiliary input Alarm condition and 
Supervision condition.
6.
Download the configuration changes to the processor.
Gate sensor module calibration
GSM calibration involves testing the gate to ensure that the detection parameter settings will 
detect a valid intrusion (see G6DA0209 FlexZone Detection tests). The recommended method to 
simulate a cut intrusion is to strike the fence fabric with the blade of a screwdriver. Hold the 
screwdriver a few inches away from the fence and flip your wrist to lightly strike the fence. Practice 
this to develop a consistent motion that applies a similar amount of force with each impact. Strike 
the fence at the same location for each test, waiting at least 2 seconds between impacts. The best 
Note
Senstar recommends leaving the target filters and the GSM’s detection 
parameters at the default settings for the calibration procedure. Adjust the 
Target Filters only if you are experiencing an unacceptable NAR. 
Note
Before beginning the GSM calibration, perform a shake test to ensure the 
gate is secure and has no loose fittings that may cause nuisance alarms 
during windy conditions. Grip the fence fabric in the middle of the gate and 
apply a pushing /pulling motion with increasing force.