Digital Security Controls Ltd. 09GS260L User Manual

Page of 33
26
address must be entered as four 3-digit entries (e.g. 192.168.1.101).  Each 3-digit segment of the address must be within a valid 
range of 000 to 255.  
Option 104: Ethernet Receiver 1 Local Port
Default (3060)
You can use this option to set the value of the local outgoing port. You can set the value of this port in case your installation is 
located behind a firewall and must be assigned a particular port number as determined by your network administrator. Valid entries 
range from 0000 to FFFF hexadecimal.
Option 105: Ethernet Receiver 1 Remote Port
Default (3061)
Option 105 determines the port of Ethernet receiver 1. Valid entries range from 0000 to FFFF hexadecimal. 
Ethernet Receiver 2 Options
Option 111: Ethernet Receiver 2 Account Code
Default (0000FFFFFF)
 The account code is used by the central station to distinguish between transmitters. This account code is used when transmitting 
signals to the central station receiver. Signals received from the control panel will use the control panel account number. Valid 
entries will range from 0000000000 to FFFFFFFFFF hexadecimal.
Option 112: Ethernet Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the Account Code to to identify the Communicator module as the central station. Valid entries 
range from 000000 to 0FFFFF hexadecimal.
Option 113: Ethernet Receiver 2 Address
Default (0.0.0.0)
Enter the Ethernet receiver 2 IP address. This information will be provided by your central station. Note that when a valid address 
has been entered, the Ethernet will be considered to be enabled and will communicate events over the Ethernet channel. The 
address must be entered as four 3-digit entries (e.g. 192.168.1.101).  Each 3-digit segment of the address must be within a valid 
range of 000 to 255.
Option 114: Ethernet Receiver 2 Local Port
Default (3065)
You can use this option to set the value of the local outgoing port. You can set the value of this port in case your installation is 
located behind a firewall and must be assigned a particular port number as determined by your network administrator. Valid entries 
range from 0000 to FFFF hexadecimal.
Option 115: Ethernet Receiver 2 Remote Port
Default (3061)
Option 115 determines the port of Ethernet receiver 2. You can set the value of this port in case your installation is located behind 
a firewall, and must be assigned a particular port number as determined by your central station system administrator. Valid entries 
range from 0000 to FFFF hexadecimal.